Product Overview
Technical Summary
| Product type | SINAMICS Power Module PM240-2, unfiltered, with integrated braking chopper |
|---|---|
| Input supply | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Rated power (LO) | 0.75 kW | 1.00 hp |
| Rated power (HO) | 0.55 kW | 0.75 hp |
| Maximum output current | 3.40 A |
| Output frequency for vector control | 0 … 200 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Connections | Plug-in screw terminals; 1.00 … 2.50 mm2 (AWG 18 … AWG 14) |
| Degree of protection | IP20 / UL open type |
| Frame size | FSA |
| Configuration exclusion | Without Control Unit and operating unit |
Key Features
Low overload: 0.75 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s at an ambient temperature of -10 … 40 °C. High overload: 0.55 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s at an ambient temperature of -10 … 50 °C.
Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz. Output: 3 AC, rated voltage 400V IEC | 480V NEC, with a maximum output current of 3.40 A.
The unfiltered Power Module has an integrated braking chopper and IP20 / UL open type protection.
Line-side and motor-end connections use plug-in screw terminals for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors. Maximum motor cable length is 50 m (164.04 ft) shielded or 100 m (328.08 ft) unshielded.
Frame size: FSA. Dimensions: 73 mm (2.87 in) width, 196 mm (7.72 in) height, and 165 mm (6.50 in) depth.
The configuration is without a Control Unit and operating unit. Released as of CU firmware version V4.6.
Frequently Asked Questions
What is the exact product type?
It is Siemens 6SL3210-1PE12-3UL1, a SINAMICS Power Module PM240-2, unfiltered, with an integrated braking chopper.
What supply does this Power Module use?
The input is 3 AC, 380 … 480 V ±10 % at 47 … 63 Hz.
What connections and motor cable lengths are supported?
The line side and motor end use plug-in screw terminals for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors. Maximum motor cable length is 50 m (164.04 ft) shielded or 100 m (328.08 ft) unshielded.
What is included in this configuration?
It is without a Control Unit and operating unit.