Product Overview
Technical Summary
| Product type | SINAMICS Power Module PM240-2, unfiltered, with integrated braking chopper |
|---|---|
| Input supply | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Rated power (LO) | 0.55 kW | 0.75 hp |
| Rated power (HO) | 0.37 kW | 0.50 hp |
| Rated current (LO) | 2.30 A input; 1.70 A output |
| Rated current (HO) | 2.00 A input; 1.30 A output |
| Maximum output current | 2.60 A |
| Output frequency | 0 … 200 Hz vector control; 0 … 550 Hz V/f control |
| Connections | Plug-in screw terminals; 1.00 … 2.50 mm2 (AWG 18 … AWG 14) |
| Firmware and lifecycle | Released as of CU firmware version V4.6; Active Product |
Key Features
Low overload: 0.55 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload: 0.37 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz.
Output: 3 AC, rated voltage 400V IEC | 480V NEC, rated current 1.70 A (LO) or 1.30 A (HO), maximum output current 2.60 A.
Integrated braking chopper. Output frequency: 0 … 200 Hz for vector control and 0 … 550 Hz for V/f control; pulse frequency: 4 kHz.
Plug-in screw terminals on the line and motor sides, for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors. Maximum motor cable length: 50 m shielded or 100 m unshielded.
Frame size FSA, IP20 / UL open type, 73 mm wide × 196 mm high × 165 mm deep, net weight 1.40 kg.
Frequently Asked Questions
What is the exact configuration of Siemens 6SL3210-1PE11-8UL1?
It is a SINAMICS Power Module PM240-2, unfiltered, with an integrated braking chopper, without Control Unit and operating unit.
What are the low-overload and high-overload ratings?
Low overload is 0.55 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s. High overload is 0.37 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s.
What connections and motor cable lengths does it have?
It has plug-in screw terminals on the line and motor sides. Maximum motor cable length is 50 m with shielding or 100 m without shielding.
What quantity, destination, and schedule should be included with this line item?
Include the requested quantity, destination, schedule context, and any additional BOM lines for quotation review.