Product Overview
Technical Summary
| Order number | 6SL3210-1KE17-5AF1 |
|---|---|
| Rated input | 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz |
| Rated power (LO) | 3.00 kW | 4.00 hp |
| Rated power (HO) | 2.20 kW | 3.00 hp |
| Communication | PROFINET, EtherNet/IP |
| Digital inputs | 6 standard; 1 fail-safe |
| Analog input | 1 differential input, 10 bit resolution |
| Protection | IP20 / UL open type |
Key Features
Rated power (LO): 3.00 kW | 4.00 hp at 150% for 3s, 110% for 57s, and 100% for 240s.
Rated power (HO): 2.20 kW | 3.00 hp at 200% for 3s, 150% for 57s, and 100% for 240s.
Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
Communication: PROFINET, EtherNet/IP. Supported control techniques include V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
Standard digital inputs: 6; fail-safe digital inputs: 1; digital outputs: 1 relay changeover contact and 1 transistor; analog/digital inputs: 1 differential input; analog outputs: 1 non-isolated output; Safe Torque Off is integrated.
Frame size: FSA. Dimensions: 73 mm width x 200 mm depth. Degree of protection: IP20 / UL open type. Line-side and motor-end connections use plug-in screw terminals.
Frequently Asked Questions
What is the rated power of 6SL3210-1KE17-5AF1?
The low-overload rating is 3.00 kW | 4.00 hp, and the high-overload rating is 2.20 kW | 3.00 hp, with the stated overload conditions.
Which communication interfaces and I/O does this line item have?
It has PROFINET and EtherNet/IP communication, 6 standard digital inputs, 1 fail-safe digital input, 1 differential analog/digital input, 1 non-isolated analog output, and 1 relay changeover contact plus 1 transistor output.
How is the unit connected and mounted?
The line-side and motor-end connections use plug-in screw terminals. The frame size is FSA, and protection is IP20 / UL open type.
What should be included in a quotation request for this item?
Include the requested quantity, destination, schedule context, and any additional BOM line items requiring quotation review.