Product Overview
Technical Summary
| Input voltage | 380 … 480 V +10 % -20 % |
|---|---|
| Line frequency | 47 … 63 Hz |
| Rated power, low overload | 5.50 kW | 7.50 hp |
| Rated power, high overload | 4.00 kW | 5.00 hp |
| Output frequency for V/f control | 0 … 550 Hz |
| Output frequency for vector control | 0 … 240 Hz |
| Communication | PROFIBUS DP |
| Digital inputs | 6 standard; 1 fail-safe |
| Analog inputs and outputs | 1 differential analog input; 1 non-isolated analog output |
| Cooling | Air cooling using an integrated fan |
| Protection | IP20 / UL open type |
| Frame size | FSB |
Key Features
Low overload: 5.50 kW at 150% for 3s, 110% for 57s, and 100% for 240s. High overload: 4.00 kW at 200% for 3s, 150% for 57s, and 100% for 240s.
Input: 3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz. Output: 3 AC, rated voltage 400V IEC | 480V NEC, with output frequency up to 0 … 550 Hz for V/f control.
The interface has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, and 1 non-isolated analog output. Communication: PROFIBUS DP.
Supported control includes V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control. Vector control with sensor and encoderless torque control are not supported.
Line-side, motor-end, and DC-link connections use plug-in screw terminals. The DC link supports a maximum line length of 15 m (49.21 ft); PE connection is on the housing with an M4 screw.
Protection: IP20 / UL open type. Frame size: FSB. Dimensions: 100 mm width and 203 mm depth. Net weight: 2.30 kg (5.07 lb).
Frequently Asked Questions
What is the exact identity of this Siemens line item?
It is 6SL3210-1KE21-3AP1, a Siemens SINAMICS G120C compact converter.
What input supply does 6SL3210-1KE21-3AP1 use?
Input: 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
Which control methods are supported?
It supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
What communication and I/O are included?
Communication is PROFIBUS DP. The I/O includes 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential analog input, and 1 non-isolated analog output.
What project details should accompany a quotation request?
Provide the requested quantity, destination, schedule context, and any additional BOM line items for quotation review.