Product Overview
Technical Summary
| Rated power | PN=0.82kW |
|---|---|
| DC voltage | UDC=600V |
| Standstill torque | M0=3Nm (100K) |
| Rated speed | NN=3000rpm |
| Cooling | Naturally cooled |
| Mounting | Frame size IMB 5 (IM V1, IM V3), flange 1 |
| Feedback | 2-pole resolver (resolver P=1) |
| Power connector | Rotatable |
| Shaft | Fitted key, tolerance N |
| Holding brake | Without holding brake |
| Degree of protection | IP64 |
Key Features
PN=0.82kW; M0=3Nm (100K); NN=3000rpm.
UDC=600V.
2-pole resolver (resolver P=1) and rotatable power connector.
Naturally cooled; frame size IMB 5 (IM V1, IM V3); flange 1; shaft with fitted key, tolerance N.
Without holding brake; degree of protection IP64.
Product cancellation.
Frequently Asked Questions
What ratings apply to Siemens 1FK7042-2AF71-1TA0?
PN=0.82kW, UDC=600V, M0=3Nm (100K), and NN=3000rpm.
What feedback and connector configuration does it have?
It has a 2-pole resolver (resolver P=1) and a rotatable power connector.
What mechanical configuration should be retained in the BOM?
It is naturally cooled, with frame size IMB 5 (IM V1, IM V3), flange 1, and a shaft with fitted key, tolerance N.
Does this configuration include a holding brake?
It is without a holding brake.
What project details should accompany a quotation request?
Provide the requested quantity, destination, schedule, and any additional BOM lines.