Product Overview
Technical Summary
| Rated power | PN=0.94 kW |
|---|---|
| DC link voltage | UDC=300 V |
| Rated speed | NN=3000 rpm |
| Cooling | Naturally cooled |
| Mounting | IMB 5 (IM V1, IM V3), flange 1 |
| Feedback | Absolute singleturn encoder, 32 S/R; multiturn encoder, 4096 rotations, with EnDat interface (encoder AM32S/R) |
| Power connection | Rotatable power connector |
| Protection | IP65 |
| Holding brake | Without holding brake |
| Shaft | Fitted key, tolerance N |
| Lifecycle | Product cancellation |
Key Features
PN=0.94 kW; UDC=300 V; NN=3000 rpm.
Absolute singleturn encoder, 32 S/R, and multiturn encoder, 4096 rotations, with EnDat interface (encoder AM32S/R).
IMB 5 mounting (IM V1, IM V3), flange 1, shaft with fitted key and tolerance N.
KTY temperature sensor and rotatable power connector; naturally cooled.
Degree of protection IP65; without holding brake.
Product cancellation.
Frequently Asked Questions
What is the exact motor line item?
It is the Siemens SIMOTICS S synchronous motor 1FK7043-4CF21-1GA1.
What are the motor ratings?
PN=0.94 kW, UDC=300 V and NN=3000 rpm.
What feedback and connector configuration does it have?
It has an absolute singleturn encoder, 32 S/R, and multiturn encoder, 4096 rotations, with EnDat interface (encoder AM32S/R), plus a rotatable power connector.
What mechanical and brake configuration should be retained in the quotation?
It has IMB 5 mounting (IM V1, IM V3), flange 1, a shaft with fitted key and tolerance N, and is without holding brake.
What project details should accompany this line item?
Provide the requested quantity, destination, schedule context and any additional BOM lines.