Product Overview
Technical Summary
| Rated power | 2 kW |
|---|---|
| Supply voltage | 600 V UDC |
| Rated speed | 3,000 rpm (100 K) |
| Rated torque | 6.5 Nm (100 K) |
| Motor type | Permanent-magnet synchronous motor; High Dynamic |
| Feedback | Resolver R14DQ: resolver 14 bits (resolution 16384, internal 2-pole) |
| Mounting | IM B5 (IM V1, IM V3) |
| Connections | Rotatable connectors for signals and power; M40 |
| Shaft | Plain shaft |
| Holding brake | Permanent-magnet brake; holding torque 22.0 Nm |
| Cooling | Natural cooling |
| Protection | IP64 |
Key Features
Rated speed: 3,000 rpm (100 K); rated torque: 6.5 Nm (100 K); rated current: 7.0 A.
Permanent-magnet synchronous motor, High Dynamic, with natural cooling and 8 poles.
Resolver R14DQ: 14 bits, resolution 16384, internal 2-pole; electrical connectors for signals and power are rotatable; connector size: M40.
Design: IM B5 (IM V1, IM V3); plain shaft; radial runout tolerance: 0.050 mm; concentricity and axial runout tolerances: 0.10 mm.
Permanent-magnet brake with 22.0 Nm holding torque, DC 24 V ± 10 % power supply voltage, 0.9 A coil current, 200 ms opening time and 60 ms closing time.
Degree of protection: IP64; temperature monitoring: Pt1000 temperature sensor; housing color: Standard (Anthracite RAL 7016).
Frequently Asked Questions
What are the rated power, speed and torque of the Siemens 1FK7085-4CF71-1PH0?
Rated power is 2 kW, rated speed is 3,000 rpm (100 K), and rated torque is 6.5 Nm (100 K).
What feedback and connectors does this motor have?
It has Resolver R14DQ feedback with 14 bits and resolution 16384, plus rotatable connectors for signals and power and an M40 connector size.
What is the mechanical configuration?
The motor has IM B5 (IM V1, IM V3) design, a plain shaft, natural cooling and IP64 protection.
What holding brake is included?
It has a permanent-magnet brake with 22.0 Nm holding torque and DC 24 V ± 10 % power supply voltage.
What quantity, destination, schedule and additional BOM lines should be included in an inquiry?
Include the requested quantity, destination, schedule context and any additional project BOM lines with this line item.