Product Overview
Technical Summary
| Rated power | PN=2 kW |
|---|---|
| DC link voltage | UDC=600 V |
| Rated torque | M0=28 Nm (100 K) |
| Rated speed | NN=3000 rpm |
| Cooling | Naturally cooled |
| Mounting | Frame size IMB 5 (IM V1, IM V3), flange 1 |
| Feedback | 2-pole resolver (resolver P=1) with KTY temperature sensor |
| Power connection | Rotatable power connector |
| Shaft | Shaft with fitted key, tolerance N |
| Holding brake | Without holding brake |
| Protection | IP65 at the DE flange; IP67 |
Key Features
PN=2 kW; UDC=600 V; M0=28 Nm (100 K); NN=3000 rpm.
Naturally cooled; frame size IMB 5 (IM V1, IM V3); flange 1.
Rotatable power connector; 2-pole resolver (resolver P=1); KTY temperature sensor.
Shaft with fitted key, tolerance N; without holding brake.
Degree of protection: IP65 at the DE flange and IP67.
Product cancellation; net weight 23.002 kg.
Frequently Asked Questions
What are the rated power, voltage, torque, and speed of 1FK7086-4CF71-1TA2?
PN=2 kW, UDC=600 V, M0=28 Nm (100 K), and NN=3000 rpm.
What feedback and temperature sensing does this motor have?
It has a 2-pole resolver (resolver P=1) and a KTY temperature sensor.
What mechanical configuration and protection does it use?
It is naturally cooled, with frame size IMB 5 (IM V1, IM V3), flange 1, a fitted-key shaft with tolerance N, IP65 at the DE flange, and IP67 protection.
Does the 1FK7086-4CF71-1TA2 include a holding brake?
It is without a holding brake.
What should be included with this motor in a project quotation request?
Provide the requested quantity, destination, schedule, and any additional BOM line items.