Product Overview
Technical Summary
| Motor type | SIMOTICS M compact asynchronous motor |
|---|---|
| Performance points | 1500 r/min: 22 kW, 140 Nm, 56 A, 308 V; 1750 r/min: 25 kW, 136 Nm, 56 A, 352 V; 2000 r/min: 28 kW, 134 Nm, 55 A, 401 V; 2200 r/min: 30 kW, 130 Nm, 53 A, 440 V |
| Cooling | Forced ventilation; direction of air flow NDE–> DE |
| Protection | IP55 degree of protection |
| Feedback | Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) |
| Temperature sensor | KTY 84-130 |
| Mounting | Design IM B35 (IM V15, (IM V35)) |
| Shaft | Shaft with fitted key; HALF-KEY BALANCING |
| Bearing | STANDARD WITH FIXED BEARING |
| Terminal box | Above; cable entry on the right |
| Signal connection | D-end |
| Lifecycle | Product cancellation |
Key Features
1500 r/min: 22 kW, 140 Nm, 56 A, 308 V; 1750 r/min: 25 kW, 136 Nm, 56 A, 352 V; 2000 r/min: 28 kW, 134 Nm, 55 A, 401 V; 2200 r/min: 30 kW, 130 Nm, 53 A, 440 V.
Incremental encoder HTL 2048 S/R (encoder HTL2048S/R) with temperature sensor KTY 84-130.
Forced ventilation; direction of air flow NDE–> DE; IP55 degree of protection.
Design IM B35 (IM V15, (IM V35)); shaft with fitted key; HALF-KEY BALANCING; bearing standard with fixed bearing; vibration severity grade R/A; flange accuracy R.
Terminal box above, cable entry on the right, and signal connection D-end.
Product cancellation.
Frequently Asked Questions
What motor ratings are associated with Siemens 1PH8137-1JF13-2BA1?
The supplied ratings are 1500 r/min: 22 kW, 140 Nm, 56 A, 308 V; 1750 r/min: 25 kW, 136 Nm, 56 A, 352 V; 2000 r/min: 28 kW, 134 Nm, 55 A, 401 V; and 2200 r/min: 30 kW, 130 Nm, 53 A, 440 V.
What feedback and temperature-sensor configuration does this line item have?
It has an incremental encoder HTL 2048 S/R (encoder HTL2048S/R) and a KTY 84-130 temperature sensor.
What mechanical and terminal configuration should be retained in the quotation?
Retain IM B35 (IM V15, (IM V35)) design, a shaft with fitted key, HALF-KEY BALANCING, standard bearing with fixed bearing, terminal box above, cable entry on the right, and signal connection D-end.
What should I provide for a project quotation request?
Provide the exact line item, requested quantity, destination, schedule context, and any additional BOM lines.