Product Overview
Technical Summary
| Product type | SIMOTICS M compact synchronous motor |
|---|---|
| Rated speed and performance | 2000 r/min, 44.4 kW, 212 Nm |
| Additional performance rating | 2300 r/min, 50.5 kW, 210 Nm |
| Additional performance rating 2 | 2650 r/min, 56.8 kW, 205 Nm |
| Electrical ratings | 85 A, 371 V; 84 A, 424 V; 83 A, 449 V |
| Cooling | Water cooling |
| Degree of protection | IP65 |
| Feedback | Incremental encoder SIN/COS 1 VPP, 2048 S/R with C and D track |
| Temperature sensor | KTY 84-130 |
| Mounting and shaft | DESIGN IM B5 (IMV 1, IM V3), plain shaft without fitted key |
| Connections | Terminal box above; cable entry on the left; signal connection D-end |
| Lifecycle | Product cancellation |
Key Features
44.4 kW, 212 Nm and 2000 r/min; additional ratings are 50.5 kW, 210 Nm and 2300 r/min, or 56.8 kW, 205 Nm and 2650 r/min.
Current and voltage ratings are 85 A at 371 V, 84 A at 424 V, or 83 A at 449 V, respectively.
Incremental encoder SIN/COS 1 VPP, 2048 S/R with C and D track, encoder IC2048S/R, plus temperature sensor KTY 84-130.
Water cooling with IP65 degree of protection.
DESIGN IM B5 (IMV 1, IM V3), plain shaft without fitted key, standard bearing with fixed bearing, and flange accuracy R.
Terminal box above, cable entry on the left, signal connection D-end. Product cancellation.
Frequently Asked Questions
What is the exact Siemens motor line item?
It is Siemens 1PH8137-2MG22-0BB1, a SIMOTICS M compact synchronous motor.
What performance ratings does this motor have?
The ratings are 2000 r/min at 44.4 kW and 212 Nm; 2300 r/min at 50.5 kW and 210 Nm; or 2650 r/min at 56.8 kW and 205 Nm.
What feedback and temperature sensing are included?
It has an incremental SIN/COS 1 VPP 2048 S/R encoder with C and D track, encoder IC2048S/R, and a KTY 84-130 temperature sensor.
What mechanical and connection details should be retained in the quotation request?
Retain water cooling, IP65, DESIGN IM B5 (IMV 1, IM V3), plain shaft without fitted key, terminal box above, cable entry on the left, and signal connection D-end. Also provide requested quantity, destination, schedule, and any additional BOM lines.