Product Overview
Technical Summary
| Product type | SIMOTICS M compact synchronous motor |
|---|---|
| Speed and rating | 1500 r/min: 61 kW, 390 Nm, 119 A at 340 V; 1750 r/min: 69 kW, 375 Nm, 115 A at 395 V; 2000 r/min: 74 kW, 355 Nm, 110 A at 445 V |
| Cooling | Forced ventilation |
| Air-flow direction | NDE–> DE |
| Encoder | Incremental SIN/COS 1 VPP, 2048 S/R, with C and D track; encoder IC2048S/R |
| Mounting design | IM B35 (IM V15, (IM V35)) |
| Shaft | Fitted key; half-key balancing |
| Bearing | Standard with fixed bearing |
| Protection | IP55 degree of protection |
| Terminal box | Above |
| Cable entry | On the right |
| Lifecycle | Product cancellation |
Key Features
1500 r/min: 61 kW, 390 Nm, 119 A at 340 V; 1750 r/min: 69 kW, 375 Nm, 115 A at 395 V; 2000 r/min: 74 kW, 355 Nm, 110 A at 445 V.
Incremental encoder SIN/COS 1 VPP, 2048 S/R, with C and D track; encoder IC2048S/R.
Forced ventilation; direction of air flow NDE–> DE.
Design IM B35 (IM V15, (IM V35)); shaft with fitted key and half-key balancing; bearing: standard with fixed bearing.
IP55 degree of protection; terminal box above; cable entry on the right; signal connection D-end.
Product cancellation; net weight: 218.000 kg. Packaging dimensions are not available.
Frequently Asked Questions
What is the exact motor line item?
It is the Siemens 1PH8165-2MF13-2BA1 SIMOTICS M compact synchronous motor.
What performance ratings are supplied for this motor?
The ratings are 61 kW, 390 Nm, 119 A at 1500 r/min and 340 V; 69 kW, 375 Nm, 115 A at 1750 r/min and 395 V; and 74 kW, 355 Nm, 110 A at 2000 r/min and 445 V.
Which feedback device and mounting design does it have?
It has an incremental SIN/COS 1 VPP, 2048 S/R encoder with C and D track, and design IM B35 (IM V15, (IM V35)).
What cooling, protection, and connection details should be retained?
It has forced ventilation, IP55 degree of protection, a terminal box above, cable entry on the right, and signal connection D-end.
What should I provide for a project quotation request?
Provide the requested quantity, destination, schedule context, and any additional BOM lines.