Product Overview
Technical Summary
| Motor type | SIMOTICS M compact asynchronous motor |
|---|---|
| Rated speed variants | 1000 r/min; 1150 r/min; 1350 r/min |
| Power variants | 92 kW; 105 kW; 120 kW |
| Torque variants | 879 Nm; 872 Nm; 849 Nm |
| Voltage variants | 340 V; 390 V; 460 V |
| Current variants | 194 A; 192 A; 188 A |
| Feedback | Incremental Encoder HTL 1024 S/R |
| Cooling | Forced ventilation, air-flow direction DE–>NDE |
| Protection | IP55 degree of protection |
| Mounting design | IM B3, IMB6, IMB7, IMB8, IMV6 |
Key Features
1000 r/min: 92 kW, 879 Nm, 194 A, 340 V; 1150 r/min: 105 kW, 872 Nm, 192 A, 390 V; 1350 r/min: 120 kW, 849 Nm, 188 A, 460 V.
Incremental Encoder HTL 1024 S/R, also identified as encoder HTL1024S/R.
Forced ventilation with air-flow direction DE–>NDE and IP55 degree of protection.
DESIGN IM B3, with IMB6, IMB7, IMB8 and IMV6 options; shaft with fitted key.
HALF-KEY BALANCING; bearing: standard; vibration severity grade A; shaft A; flange accuracy grade N.
Terminal box above; cable entry on the right; signal connection D-end.
Frequently Asked Questions
What performance variants does the 1PH8226-1HD00-2AA1 have?
It has 1000 r/min at 92 kW, 879 Nm, 194 A and 340 V; 1150 r/min at 105 kW, 872 Nm, 192 A and 390 V; and 1350 r/min at 120 kW, 849 Nm, 188 A and 460 V.
What feedback device is included?
It has an incremental Encoder HTL 1024 S/R, also identified as encoder HTL1024S/R.
What are the cooling, protection and mounting details?
It has forced ventilation with air-flow direction DE–>NDE, IP55 protection and DESIGN IM B3, with IMB6, IMB7, IMB8 and IMV6 options.
What mechanical and connection details should be retained in the quotation?
Retain the fitted-key shaft, HALF-KEY BALANCING, standard bearing, vibration severity grade A, shaft A, flange accuracy grade N, terminal box above, right-side cable entry and D-end signal connection.