Product Overview
Technical Summary
| Product type | SINAMICS G120 PM 240-2 push-through power module |
|---|---|
| High-overload power | 45 kW at 200% 3 s, 150% 57 s, 100% 240 s; ambient temperature -20 to +50 °C (HO) |
| Low-overload power | 55 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature -20 to +40 °C (LO) |
| Supply | 380-480 V 3 AC +10/-20%, 47-63 Hz |
| Braking | Integrated braking chopper |
| Filtering | Unfiltered |
| Protection | IP20 |
| Excluded items | Control Unit and operating unit |
| Firmware release | Released as of CU firmware version V4.7 SP6 |
| Lifecycle | Product cancellation |
Key Features
45 kW at 200% for 3 s, 150% for 57 s and 100% for 240 s; ambient temperature -20 to +50 °C (HO).
55 kW at 150% for 3 s, 110% for 57 s and 100% for 240 s; ambient temperature -20 to +40 °C (LO).
380-480 V 3 AC +10/-20%, 47-63 Hz.
PM 240-2 push-through, unfiltered, with integrated braking chopper; dimensions 615x354x237 (HxWxD).
IP20; without Control Unit and operating unit.
Product cancellation; released as of CU firmware version V4.7 SP6.
Frequently Asked Questions
What is the exact Siemens line item?
It is 6SL3211-1PE31-1UL0, a SINAMICS G120 PM 240-2 push-through power module.
What are the high- and low-overload ratings?
High overload is 45 kW at 200% for 3 s, 150% for 57 s and 100% for 240 s at -20 to +50 °C (HO). Low overload is 55 kW at 150% for 3 s, 110% for 57 s and 100% for 240 s at -20 to +40 °C (LO).
What is included in this configuration?
It is without Control Unit and operating unit. The module is unfiltered and has an integrated braking chopper.
What details should accompany a quotation request?
Provide the requested quantity, destination, schedule context and any additional BOM line items.