Product Overview
Technical Summary
| Product type | SINAMICS Power Module PM240-2, unfiltered |
|---|---|
| High-overload power | 1.1 kW at 200% 3 s, 150% 57 s, 100% 240 s; ambient temperature -10 … +50 °C |
| Low-overload power | 1.5 kW at 150% 3 s, 110% 57 s, 100% 240 s; ambient temperature -10 … +40 °C |
| Input supply | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Output current | 4.10 A (LO), 3.10 A (HO); maximum 6.20 A |
| Output frequency | 0 … 200 Hz for vector control; 0 … 550 Hz for V/f control |
| Connections | Plug-in screw terminals; 1.00 … 2.50 mm2 (AWG 18 … AWG 14) |
| Frame size | FSA |
| Protection | IP20 / UL open type |
| Exclusions | Without Control Unit and operating unit |
Key Features
High overload: 1.1 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s at -10 to +50 °C ambient temperature; low overload: 1.5 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s at -10 to +40 °C ambient temperature.
Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz; rated current is 5.50 A for low overload and 4.70 A for high overload.
Output: 3 AC, 400V IEC | 480V NEC; maximum output current is 6.20 A, pulse frequency is 4 kHz, and output frequency is 0 … 200 Hz for vector control or 0 … 550 Hz for V/f control.
Line-side and motor-end connections use plug-in screw terminals for 1.00 … 2.50 mm2 (AWG 18 … AWG 14) conductors. Maximum motor cable length is 50 m (164.04 ft) shielded or 100 m (328.08 ft) unshielded.
FSA frame size; dimensions are 196 mm high × 73 mm wide × 165 mm deep, with IP20 / UL open type protection.
The power module is unfiltered and supplied without a Control Unit and operating unit.
Frequently Asked Questions
What is the exact Siemens line item?
It is Siemens 6SL3210-1PE14-3UL1, a SINAMICS Power Module PM240-2.
What are the high-overload and low-overload ratings?
High overload is 1.1 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s at -10 to +50 °C. Low overload is 1.5 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s at -10 to +40 °C.
What connections and motor cable lengths are specified?
Both line-side and motor-end connections use plug-in screw terminals for 1.00 … 2.50 mm2 (AWG 18 … AWG 14). Maximum length is 50 m (164.04 ft) for shielded cable or 100 m (328.08 ft) for unshielded cable.
What is included in the configuration?
It is without a Control Unit and operating unit, and it is unfiltered.
Can this line item be added to a project quotation?
Provide the requested quantity, destination, schedule context, and any additional BOM lines for quotation review.