Product Overview
Technical Summary
| Product type | SINAMICS Power Module PM240-2 |
|---|---|
| Input supply | 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz |
| Rated output power (LO) | 3.00 kW | 4.00 hp |
| Rated output power (HO) | 2.20 kW | 3.00 hp |
| Maximum output current | 11.80 A |
| Output frequency for vector control | 0 … 200 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Connections | Plug-in screw terminals, line side and motor end |
| Degree of protection | IP20 / UL open type |
| Configuration | Unfiltered with integrated braking chopper; without Control Unit and operating unit |
| Lifecycle | Active Product |
Key Features
Power high overload: 2.20 kW at 200% for 3 s, 150% for 57 s, and 100% for 240 s at -10 … 50 °C ambient temperature. Power low overload: 3 kW at 150% for 3 s, 110% for 57 s, and 100% for 240 s at -10 … 40 °C ambient temperature.
Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz. Output rated power: 3.00 kW | 4.00 hp (LO) and 2.20 kW | 3.00 hp (HO).
Output frequency for vector control: 0 … 200 Hz. Output frequency for V/f control: 0 … 550 Hz. Pulse frequency: 4 kHz.
Line-side and motor-end connections use plug-in screw terminals for 1.50 … 2.50 mm2 (AWG 16 … AWG 14) conductors. Maximum motor cable length: 50 m (164.04 ft) shielded or 100 m (328.08 ft) unshielded.
Frame size: FSA. Dimensions: 73 mm (2.87 in) width, 196 mm (7.72 in) height, and 165 mm (6.50 in) depth. Degree of protection: IP20 / UL open type.
The unit is unfiltered, with an integrated braking chopper, and is without a Control Unit and operating unit. Released as of CU firmware version V4.6.
Frequently Asked Questions
What is the exact Siemens line item?
The exact line item is Siemens 6SL3210-1PE18-0UL1, a SINAMICS Power Module PM240-2.
What input supply does 6SL3210-1PE18-0UL1 use?
Input: 3 AC, 380 … 480 V ±10 %, 47 … 63 Hz.
What configuration is supplied?
It is unfiltered, with an integrated braking chopper, and without a Control Unit and operating unit.
What should be included for a project quotation?
Provide the requested quantity, destination, schedule context, and any additional BOM line items.