Product Overview
Applications
Positioning of rapid/slow traverse drives.
Technical Summary
| Module type | SIMATIC S7-300 FM 351 positioning module |
|---|---|
| Supply voltage | 24 V DC rated; permissible range 20.4 V to 28.8 V |
| Digital inputs | 8 |
| Digital outputs | 8 |
| Encoder support | Symmetrical/asymmetrical incremental encoder, absolute encoder (SSI), and 2-wire sensor |
| Required front connector | 1x 20-pin |
| Product lifecycle | Product cancellation |
| Included item | Configuration package on CD |
Key Features
FM 351 for rapid/slow traverse drives.
8 digital inputs for reference cams, reversing cams, flying actual value setting, and start/stop positioning; 8 digital outputs for rapid traverse, creep, run right, and run left.
24 V DC rated supply; permissible range 20.4 V to 28.8 V.
Supports symmetrical and asymmetrical incremental encoders, absolute encoders (SSI), and 2-wire sensors.
Required front connector: 1x 20-pin.
Product cancellation; configuration package on CD included.
Frequently Asked Questions
What is the exact configuration of 6ES7351-1AH02-0AE0?
It is a SIMATIC S7-300 FM 351 positioning module for rapid/slow traverse drives, with 8 digital inputs, 8 digital outputs, and a 24 V DC rated supply.
Which encoder types does this module support?
It supports symmetrical and asymmetrical incremental encoders, absolute encoders (SSI), and 2-wire sensors.
What front connector is required?
The required front connector is 1x 20-pin.
What should be provided for a project quotation?
Provide the requested quantity, destination, schedule context, and any additional BOM lines for quotation review.