Product Overview
Applications
Conductive charging of electric vehicles according to DIN 70121 and ISO 15118 charge operating mode 4 using CCS.
Technical Summary
| Product type | ECC PL ST |
|---|---|
| Supply voltage | 24 V DC rated; permissible range 19.2 V to 28.8 V |
| Channel capacity | 1 channel; according to IEC 61851-1 Mode 4 and DIN SPEC 70121 |
| Control Pilot | 1 Control Pilot including Powerline Green Phy |
| Digital outputs | 2 transistor outputs; 1 TRIP and 1 DQ P, both open collector |
| Analog inputs | 1; Plug Present according to IEC 61851 |
| Analog outputs | 1; Control Pilot including Powerline Green Phy, according to DIN SPEC 70121 |
| Switching capacity | 0.6 A maximum per digital output with resistive load |
| Engineering | STEP 7 V16 or higher in TIA Portal |
| Mounting | Standard rail; horizontal or vertical |
| Protection | IP20 |
| Firmware | V1.1.13 |
Key Features
Technology module for conductive charging of electric vehicles according to DIN 70121; vehicle communication according to IEC 61851 Mode 4.
1 channel; 1 Control Pilot including Powerline Green Phy, 1 Plug Present / Proximity Pilot, and 1 digital output for the TRIP function as open collector.
24 V DC rated supply with a permissible range of 19.2 V to 28.8 V and reverse polarity protection against destruction.
2 transistor digital outputs: 1 TRIP function and 1 DQ P, both as open collector; short-circuit proof and current-sinking.
Configurable/integrated from STEP 7 V16 or higher in TIA Portal; mounting on a standard rail in horizontal or vertical position.
IP20 protection; green PWR and channel-status LEDs, plus a green/red DIAG LED; diagnostic alarm available.
Frequently Asked Questions
What is the exact Siemens line item?
It is Siemens 6FE1242-6TM20-0BB1, product type ECC PL ST.
What supply voltage does the module use?
Supply is 24 V DC rated, with a permissible range of 19.2 V to 28.8 V.
How many channels and outputs does it have?
It has 1 channel and 2 transistor digital outputs: 1 TRIP output and 1 DQ P output, both as open collector.
How is the module mounted and engineered?
It mounts on a standard rail in horizontal or vertical position and is configurable/integrated from STEP 7 V16 or higher in TIA Portal.
What should I include for a project quotation?
Include the exact line item, requested quantity, destination, schedule context, and any additional BOM lines.