Product Overview
Technical Summary
| Input voltage | 380 … 480 V +10 % -20 % |
|---|---|
| Input frequency | 47 … 63 Hz |
| Rated power (LO) | 0.55 kW | 0.75 hp |
| Rated power (HO) | 0.37 kW | 0.50 hp |
| Maximum output current | 2.60 A |
| Output frequency for vector control | 0 … 240 Hz |
| Output frequency for V/f control | 0 … 550 Hz |
| Communication | PROFIBUS DP |
| I/O configuration | 6 digital inputs, 1 fail-safe digital input, 1 relay changeover contact output, 1 transistor output, 1 differential analog/digital input and 1 non-isolated analog output |
| Protection | IP20 / UL open type |
| Frame size | FSAA |
Key Features
3 AC input, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
Rated power is 0.55 kW at low overload and 0.37 kW at high overload.
Supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control. Vector control with sensor and encoderless torque control are not supported.
Provides 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact output, 1 transistor output, 1 differential analog/digital input and 1 non-isolated analog output.
Communication: PROFIBUS DP. Integrated filter: Class A.
Frame size FSAA, IP20 / UL open type, 73 mm width, 155 mm depth and 1.40 kg net weight.
Frequently Asked Questions
What is the input rating of 6SL3210-1KE11-8AP2?
Its input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
Which control techniques are supported?
It supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law and sensorless vector control.
What communication and I/O are provided?
Communication is PROFIBUS DP. The I/O includes 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact output, 1 transistor output, 1 differential analog/digital input and 1 non-isolated analog output.
How is this line item configured mechanically?
It has FSAA frame size, IP20 / UL open type protection, 73 mm width, 155 mm depth and 1.40 kg net weight.
What quantity, destination, schedule and additional BOM lines should be included in an inquiry?
Include the requested quantity, destination, schedule context and any additional BOM line items in the project quotation request.