Product Overview
Technical Summary
| Rated input voltage | 380 … 480 V +10 % -20 % |
|---|---|
| Rated input frequency | 47 … 63 Hz |
| Rated output power, LO | 15.00 kW | 20.00 hp |
| Rated output power, HO | 11.00 kW | 15.00 hp |
| Communication | PROFIBUS DP |
| Standard digital inputs | 6 |
| Fail-safe digital inputs | 1 |
| Analog / digital inputs | 1 (Differential input) |
| Degree of protection | IP20 / UL open type |
| Frame size | FSC |
Key Features
3 AC, 380 … 480 V +10 % -20 %, 47 … 63 Hz.
15.00 kW | 20.00 hp at low overload (LO); 11.00 kW | 15.00 hp at high overload (HO).
LO: 150% for 3s, 110% for 57s, 100% for 240s; HO: 200% for 3s, 150% for 57s, 100% for 240s.
PROFIBUS DP; V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control.
6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input, 1 non-isolated analog output, and integrated Safe Torque Off.
Frame size FSC; IP20 / UL open type; width 140 mm, depth 203 mm; air cooling using an integrated fan.
Frequently Asked Questions
What is the rated input for 6SL3210-1KE23-2AP1?
The input is 3 AC, 380 … 480 V +10 % -20 % at 47 … 63 Hz.
Which communication interface does this line item have?
It has PROFIBUS DP.
What control and feedback functions are supported?
It supports V/f linear / square-law / parameterizable, V/f with flux current control (FCC), V/f ECO linear / square-law, and sensorless vector control. Vector control, with sensor; encoderless torque control; and torque control, with encoder are not supported.
What I/O configuration should be retained in the quotation?
The configuration has 6 standard digital inputs, 1 fail-safe digital input, 1 relay changeover contact, 1 transistor output, 1 differential input, and 1 non-isolated analog output.